Review



standard surface electrocardiogram  (ADInstruments)


Bioz Verified Symbol ADInstruments is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 98

    Structured Review

    ADInstruments standard surface electrocardiogram
    Standard Surface Electrocardiogram, supplied by ADInstruments, used in various techniques. Bioz Stars score: 98/100, based on 3549 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/standard surface electrocardiogram/product/ADInstruments
    Average 98 stars, based on 3549 article reviews
    standard surface electrocardiogram - by Bioz Stars, 2026-05
    98/100 stars

    Images



    Similar Products

    98
    ADInstruments standard surface electrocardiogram
    Standard Surface Electrocardiogram, supplied by ADInstruments, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/standard surface electrocardiogram/product/ADInstruments
    Average 98 stars, based on 1 article reviews
    standard surface electrocardiogram - by Bioz Stars, 2026-05
    98/100 stars
      Buy from Supplier

    90
    Data Sciences International surface electrocardiogram (ecg) p3 plus
    Transplantation of gut microbiota from aged mice increases susceptibility to arrhythmia (A) Sample <t>ECG</t> traces of four different types of arrhythmic events: ventricular premature beats (VPB), ventricular tachycardia (VT), atrial fibrillation (AF), and atrioventricular block (AVB). (B) Summary the inducibility of VPB, VT, AF, and AVB in young and aged mice. Numbers in parentheses indicate the number of mice that were induced into VPB, VT, AF, AVB following ISO treated ( n = 6/per group). Data analyzed by Fischer’s exact test. (C) Differences in heart rates, PR intervals, QRS intervals, R amplitude, P duration and P amplitude among young-young FMT, young-aged FMT, aged-aged FMT and aged-young FMT mice ( n = 6/per group). Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (D) Representative western blot and quantification of Cx43, Cx40, Nav1.5, Cav1.2, Serca-2A, Kv4.2, IL-6, IL-10, IL-1β, TNF-α, TGF-β, α-SMA, GAPDH in ventricular and atrial tissue of young-young FMT, young-aged FMT, aged-aged FMT and aged-young FMT mice ( n = 6/per group). GAPDH was used for internal normalization. Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (E) Representative micrographs of Cx43 signal in ventricular and Cx40 in stained atrial sections visualized ( n = 6/per group). Cx43 indicates Connexin 43; Cx40, Connexin 40; ISO, isoproterenol; IL-6, Interleukin-6; TNF-α, tumor necrosis factor-α; TGF-β, transforming growth factor β.
    Surface Electrocardiogram (Ecg) P3 Plus, supplied by Data Sciences International, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/surface electrocardiogram (ecg) p3 plus/product/Data Sciences International
    Average 90 stars, based on 1 article reviews
    surface electrocardiogram (ecg) p3 plus - by Bioz Stars, 2026-05
    90/100 stars
      Buy from Supplier

    90
    PRUCKA ENGINEERING INC 12-lead surface electrocardiogram (ecg)
    Transplantation of gut microbiota from aged mice increases susceptibility to arrhythmia (A) Sample <t>ECG</t> traces of four different types of arrhythmic events: ventricular premature beats (VPB), ventricular tachycardia (VT), atrial fibrillation (AF), and atrioventricular block (AVB). (B) Summary the inducibility of VPB, VT, AF, and AVB in young and aged mice. Numbers in parentheses indicate the number of mice that were induced into VPB, VT, AF, AVB following ISO treated ( n = 6/per group). Data analyzed by Fischer’s exact test. (C) Differences in heart rates, PR intervals, QRS intervals, R amplitude, P duration and P amplitude among young-young FMT, young-aged FMT, aged-aged FMT and aged-young FMT mice ( n = 6/per group). Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (D) Representative western blot and quantification of Cx43, Cx40, Nav1.5, Cav1.2, Serca-2A, Kv4.2, IL-6, IL-10, IL-1β, TNF-α, TGF-β, α-SMA, GAPDH in ventricular and atrial tissue of young-young FMT, young-aged FMT, aged-aged FMT and aged-young FMT mice ( n = 6/per group). GAPDH was used for internal normalization. Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (E) Representative micrographs of Cx43 signal in ventricular and Cx40 in stained atrial sections visualized ( n = 6/per group). Cx43 indicates Connexin 43; Cx40, Connexin 40; ISO, isoproterenol; IL-6, Interleukin-6; TNF-α, tumor necrosis factor-α; TGF-β, transforming growth factor β.
    12 Lead Surface Electrocardiogram (Ecg), supplied by PRUCKA ENGINEERING INC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/12-lead surface electrocardiogram (ecg)/product/PRUCKA ENGINEERING INC
    Average 90 stars, based on 1 article reviews
    12-lead surface electrocardiogram (ecg) - by Bioz Stars, 2026-05
    90/100 stars
      Buy from Supplier

    90
    Abbott Laboratories surface electrocardiograms (ecg)
    Transplantation of gut microbiota from aged mice increases susceptibility to arrhythmia (A) Sample <t>ECG</t> traces of four different types of arrhythmic events: ventricular premature beats (VPB), ventricular tachycardia (VT), atrial fibrillation (AF), and atrioventricular block (AVB). (B) Summary the inducibility of VPB, VT, AF, and AVB in young and aged mice. Numbers in parentheses indicate the number of mice that were induced into VPB, VT, AF, AVB following ISO treated ( n = 6/per group). Data analyzed by Fischer’s exact test. (C) Differences in heart rates, PR intervals, QRS intervals, R amplitude, P duration and P amplitude among young-young FMT, young-aged FMT, aged-aged FMT and aged-young FMT mice ( n = 6/per group). Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (D) Representative western blot and quantification of Cx43, Cx40, Nav1.5, Cav1.2, Serca-2A, Kv4.2, IL-6, IL-10, IL-1β, TNF-α, TGF-β, α-SMA, GAPDH in ventricular and atrial tissue of young-young FMT, young-aged FMT, aged-aged FMT and aged-young FMT mice ( n = 6/per group). GAPDH was used for internal normalization. Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (E) Representative micrographs of Cx43 signal in ventricular and Cx40 in stained atrial sections visualized ( n = 6/per group). Cx43 indicates Connexin 43; Cx40, Connexin 40; ISO, isoproterenol; IL-6, Interleukin-6; TNF-α, tumor necrosis factor-α; TGF-β, transforming growth factor β.
    Surface Electrocardiograms (Ecg), supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/surface electrocardiograms (ecg)/product/Abbott Laboratories
    Average 90 stars, based on 1 article reviews
    surface electrocardiograms (ecg) - by Bioz Stars, 2026-05
    90/100 stars
      Buy from Supplier

    90
    ADInstruments surface electrocardiogram (ecg)
    Transplantation of gut microbiota from aged mice increases susceptibility to arrhythmia (A) Sample <t>ECG</t> traces of four different types of arrhythmic events: ventricular premature beats (VPB), ventricular tachycardia (VT), atrial fibrillation (AF), and atrioventricular block (AVB). (B) Summary the inducibility of VPB, VT, AF, and AVB in young and aged mice. Numbers in parentheses indicate the number of mice that were induced into VPB, VT, AF, AVB following ISO treated ( n = 6/per group). Data analyzed by Fischer’s exact test. (C) Differences in heart rates, PR intervals, QRS intervals, R amplitude, P duration and P amplitude among young-young FMT, young-aged FMT, aged-aged FMT and aged-young FMT mice ( n = 6/per group). Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (D) Representative western blot and quantification of Cx43, Cx40, Nav1.5, Cav1.2, Serca-2A, Kv4.2, IL-6, IL-10, IL-1β, TNF-α, TGF-β, α-SMA, GAPDH in ventricular and atrial tissue of young-young FMT, young-aged FMT, aged-aged FMT and aged-young FMT mice ( n = 6/per group). GAPDH was used for internal normalization. Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (E) Representative micrographs of Cx43 signal in ventricular and Cx40 in stained atrial sections visualized ( n = 6/per group). Cx43 indicates Connexin 43; Cx40, Connexin 40; ISO, isoproterenol; IL-6, Interleukin-6; TNF-α, tumor necrosis factor-α; TGF-β, transforming growth factor β.
    Surface Electrocardiogram (Ecg), supplied by ADInstruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/surface electrocardiogram (ecg)/product/ADInstruments
    Average 90 stars, based on 1 article reviews
    surface electrocardiogram (ecg) - by Bioz Stars, 2026-05
    90/100 stars
      Buy from Supplier

    98
    ADInstruments surface electrocardiogram assay
    Transplantation of gut microbiota from aged mice increases susceptibility to arrhythmia (A) Sample <t>ECG</t> traces of four different types of arrhythmic events: ventricular premature beats (VPB), ventricular tachycardia (VT), atrial fibrillation (AF), and atrioventricular block (AVB). (B) Summary the inducibility of VPB, VT, AF, and AVB in young and aged mice. Numbers in parentheses indicate the number of mice that were induced into VPB, VT, AF, AVB following ISO treated ( n = 6/per group). Data analyzed by Fischer’s exact test. (C) Differences in heart rates, PR intervals, QRS intervals, R amplitude, P duration and P amplitude among young-young FMT, young-aged FMT, aged-aged FMT and aged-young FMT mice ( n = 6/per group). Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (D) Representative western blot and quantification of Cx43, Cx40, Nav1.5, Cav1.2, Serca-2A, Kv4.2, IL-6, IL-10, IL-1β, TNF-α, TGF-β, α-SMA, GAPDH in ventricular and atrial tissue of young-young FMT, young-aged FMT, aged-aged FMT and aged-young FMT mice ( n = 6/per group). GAPDH was used for internal normalization. Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (E) Representative micrographs of Cx43 signal in ventricular and Cx40 in stained atrial sections visualized ( n = 6/per group). Cx43 indicates Connexin 43; Cx40, Connexin 40; ISO, isoproterenol; IL-6, Interleukin-6; TNF-α, tumor necrosis factor-α; TGF-β, transforming growth factor β.
    Surface Electrocardiogram Assay, supplied by ADInstruments, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/surface electrocardiogram assay/product/ADInstruments
    Average 98 stars, based on 1 article reviews
    surface electrocardiogram assay - by Bioz Stars, 2026-05
    98/100 stars
      Buy from Supplier

    90
    Techman Electronics Inc surface electrocardiogram (ecg) techman biological signal acquisition system bl-420f
    Transplantation of gut microbiota from aged mice increases susceptibility to arrhythmia (A) Sample <t>ECG</t> traces of four different types of arrhythmic events: ventricular premature beats (VPB), ventricular tachycardia (VT), atrial fibrillation (AF), and atrioventricular block (AVB). (B) Summary the inducibility of VPB, VT, AF, and AVB in young and aged mice. Numbers in parentheses indicate the number of mice that were induced into VPB, VT, AF, AVB following ISO treated ( n = 6/per group). Data analyzed by Fischer’s exact test. (C) Differences in heart rates, PR intervals, QRS intervals, R amplitude, P duration and P amplitude among young-young FMT, young-aged FMT, aged-aged FMT and aged-young FMT mice ( n = 6/per group). Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (D) Representative western blot and quantification of Cx43, Cx40, Nav1.5, Cav1.2, Serca-2A, Kv4.2, IL-6, IL-10, IL-1β, TNF-α, TGF-β, α-SMA, GAPDH in ventricular and atrial tissue of young-young FMT, young-aged FMT, aged-aged FMT and aged-young FMT mice ( n = 6/per group). GAPDH was used for internal normalization. Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (E) Representative micrographs of Cx43 signal in ventricular and Cx40 in stained atrial sections visualized ( n = 6/per group). Cx43 indicates Connexin 43; Cx40, Connexin 40; ISO, isoproterenol; IL-6, Interleukin-6; TNF-α, tumor necrosis factor-α; TGF-β, transforming growth factor β.
    Surface Electrocardiogram (Ecg) Techman Biological Signal Acquisition System Bl 420f, supplied by Techman Electronics Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/surface electrocardiogram (ecg) techman biological signal acquisition system bl-420f/product/Techman Electronics Inc
    Average 90 stars, based on 1 article reviews
    surface electrocardiogram (ecg) techman biological signal acquisition system bl-420f - by Bioz Stars, 2026-05
    90/100 stars
      Buy from Supplier

    90
    FUJIFILM VisualSonics Inc surface electrocardiogram ecg
    Transplantation of gut microbiota from aged mice increases susceptibility to arrhythmia (A) Sample <t>ECG</t> traces of four different types of arrhythmic events: ventricular premature beats (VPB), ventricular tachycardia (VT), atrial fibrillation (AF), and atrioventricular block (AVB). (B) Summary the inducibility of VPB, VT, AF, and AVB in young and aged mice. Numbers in parentheses indicate the number of mice that were induced into VPB, VT, AF, AVB following ISO treated ( n = 6/per group). Data analyzed by Fischer’s exact test. (C) Differences in heart rates, PR intervals, QRS intervals, R amplitude, P duration and P amplitude among young-young FMT, young-aged FMT, aged-aged FMT and aged-young FMT mice ( n = 6/per group). Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (D) Representative western blot and quantification of Cx43, Cx40, Nav1.5, Cav1.2, Serca-2A, Kv4.2, IL-6, IL-10, IL-1β, TNF-α, TGF-β, α-SMA, GAPDH in ventricular and atrial tissue of young-young FMT, young-aged FMT, aged-aged FMT and aged-young FMT mice ( n = 6/per group). GAPDH was used for internal normalization. Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (E) Representative micrographs of Cx43 signal in ventricular and Cx40 in stained atrial sections visualized ( n = 6/per group). Cx43 indicates Connexin 43; Cx40, Connexin 40; ISO, isoproterenol; IL-6, Interleukin-6; TNF-α, tumor necrosis factor-α; TGF-β, transforming growth factor β.
    Surface Electrocardiogram Ecg, supplied by FUJIFILM VisualSonics Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/surface electrocardiogram ecg/product/FUJIFILM VisualSonics Inc
    Average 90 stars, based on 1 article reviews
    surface electrocardiogram ecg - by Bioz Stars, 2026-05
    90/100 stars
      Buy from Supplier

    90
    TEKSystems Inc surface electrocardiogram ecg b&w
    Intracardiac programmed electrical stimuli results. (A) Representative burst pacing <t>electrocardiogram</t> wave. (B) AF incidence in the four groups. (C) AF duration in the four groups. n=20 for each group. Data are presented as mean ± SD. **P<0.01 vs. the control group; # P<0.05 vs. the DM group. DM, diabetes mellitus; AF, atrial fibrillation; H 2 S, hydrogen sulfide.
    Surface Electrocardiogram Ecg B&W, supplied by TEKSystems Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/surface electrocardiogram ecg b&w/product/TEKSystems Inc
    Average 90 stars, based on 1 article reviews
    surface electrocardiogram ecg b&w - by Bioz Stars, 2026-05
    90/100 stars
      Buy from Supplier

    Image Search Results


    Transplantation of gut microbiota from aged mice increases susceptibility to arrhythmia (A) Sample ECG traces of four different types of arrhythmic events: ventricular premature beats (VPB), ventricular tachycardia (VT), atrial fibrillation (AF), and atrioventricular block (AVB). (B) Summary the inducibility of VPB, VT, AF, and AVB in young and aged mice. Numbers in parentheses indicate the number of mice that were induced into VPB, VT, AF, AVB following ISO treated ( n = 6/per group). Data analyzed by Fischer’s exact test. (C) Differences in heart rates, PR intervals, QRS intervals, R amplitude, P duration and P amplitude among young-young FMT, young-aged FMT, aged-aged FMT and aged-young FMT mice ( n = 6/per group). Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (D) Representative western blot and quantification of Cx43, Cx40, Nav1.5, Cav1.2, Serca-2A, Kv4.2, IL-6, IL-10, IL-1β, TNF-α, TGF-β, α-SMA, GAPDH in ventricular and atrial tissue of young-young FMT, young-aged FMT, aged-aged FMT and aged-young FMT mice ( n = 6/per group). GAPDH was used for internal normalization. Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (E) Representative micrographs of Cx43 signal in ventricular and Cx40 in stained atrial sections visualized ( n = 6/per group). Cx43 indicates Connexin 43; Cx40, Connexin 40; ISO, isoproterenol; IL-6, Interleukin-6; TNF-α, tumor necrosis factor-α; TGF-β, transforming growth factor β.

    Journal: iScience

    Article Title: Aged gut microbiota promotes arrhythmia susceptibility via oxidative stress

    doi: 10.1016/j.isci.2024.110888

    Figure Lengend Snippet: Transplantation of gut microbiota from aged mice increases susceptibility to arrhythmia (A) Sample ECG traces of four different types of arrhythmic events: ventricular premature beats (VPB), ventricular tachycardia (VT), atrial fibrillation (AF), and atrioventricular block (AVB). (B) Summary the inducibility of VPB, VT, AF, and AVB in young and aged mice. Numbers in parentheses indicate the number of mice that were induced into VPB, VT, AF, AVB following ISO treated ( n = 6/per group). Data analyzed by Fischer’s exact test. (C) Differences in heart rates, PR intervals, QRS intervals, R amplitude, P duration and P amplitude among young-young FMT, young-aged FMT, aged-aged FMT and aged-young FMT mice ( n = 6/per group). Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (D) Representative western blot and quantification of Cx43, Cx40, Nav1.5, Cav1.2, Serca-2A, Kv4.2, IL-6, IL-10, IL-1β, TNF-α, TGF-β, α-SMA, GAPDH in ventricular and atrial tissue of young-young FMT, young-aged FMT, aged-aged FMT and aged-young FMT mice ( n = 6/per group). GAPDH was used for internal normalization. Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (E) Representative micrographs of Cx43 signal in ventricular and Cx40 in stained atrial sections visualized ( n = 6/per group). Cx43 indicates Connexin 43; Cx40, Connexin 40; ISO, isoproterenol; IL-6, Interleukin-6; TNF-α, tumor necrosis factor-α; TGF-β, transforming growth factor β.

    Article Snippet: Surface electrocardiogram (ECG) was monitored by P3 plus (Data Sciences International), 1.5% isoflurane-oxygen mixture was anesthetized, and subcutaneous platinum electrode was placed on lead II.

    Techniques: Transplantation Assay, Blocking Assay, Western Blot, Staining

    Vitexin improved aged related arrhythmia through OLA1-Nrf2 signaling pathway (A) Experimental design for testing the anti-aging effect of vitexin on aged mice induced by 150 mg kg D-gal. (B) Sample ECG traces of three different types of arrhythmic events: ventricular premature beats (VPB), atrial fibrillation (AF), and atrioventricular block (AVB). (C) Summary of inducibility of VPB, AF, and AVB in vehicle, and vitexin treated aged mice. Numbers in parentheses indicate the number of mice that were induced into VPB, AF, AVB following ISO treated ( n = 6/per group). Data analyzed by Fischer’s exact test. And differences in heart rates, P-R intervals, QRS intervals, and R amplitude among different group ( n = 6/per group). Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (D) The examples of HE, Sirius red staining in the ventricle and atria from different group of mice ( n = 6/per group). Scale bar, 100 μm. Viteixn attenuated fibrosis in aged mice measured by Sirius red staining. Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (E and I) Cardiac, serum, colon MDA, SOD and GSH-px levels were quantified using commercial assay kits. ( n = 6/per group). Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (F) Representative western blot and quantification of Cx43, Nav1.5, Cav1.2, Serca-2A, Kv4.2, α-SMA, OLA1, Nrf2, GAPDH in ventricle and atria in the four groups ( n = 6/per group). GAPDH was used for internal normalization. Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (G) Experimental design for testing the anti-aging effect of Nrf2 activator and inhibitor on aged mice induced by 150 mg kg D-gal. Summary of inducibility of VPB, AF, and AVB in vitexin, DMF, ML385 treated aged mice. Numbers in parentheses indicate the number of mice that were induced into VPB, AF, AVB following ISO treated ( n = 6/per group). Data analyzed by Fischer’s exact test. (H) The examples of HE, Sirius red staining in the ventricle from different group of mice ( n = 6/per group). Scale bar, 100 μm. Viteixn and DMF attenuated fibrosis in aged mice measured by Sirius red staining. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. Serum levels were quantified using commercial assay kits. ( n = 6/per group). Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (J) Representative western blot and quantification of Cx43, Nav1.5, Cav1.2, Serca-2A, Kv4.2, α-SMA, OLA1, Nrf2, and GAPDH in ventricle in the four groups ( n = 6/per group). GAPDH was used for internal normalization. Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001.

    Journal: iScience

    Article Title: Aged gut microbiota promotes arrhythmia susceptibility via oxidative stress

    doi: 10.1016/j.isci.2024.110888

    Figure Lengend Snippet: Vitexin improved aged related arrhythmia through OLA1-Nrf2 signaling pathway (A) Experimental design for testing the anti-aging effect of vitexin on aged mice induced by 150 mg kg D-gal. (B) Sample ECG traces of three different types of arrhythmic events: ventricular premature beats (VPB), atrial fibrillation (AF), and atrioventricular block (AVB). (C) Summary of inducibility of VPB, AF, and AVB in vehicle, and vitexin treated aged mice. Numbers in parentheses indicate the number of mice that were induced into VPB, AF, AVB following ISO treated ( n = 6/per group). Data analyzed by Fischer’s exact test. And differences in heart rates, P-R intervals, QRS intervals, and R amplitude among different group ( n = 6/per group). Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (D) The examples of HE, Sirius red staining in the ventricle and atria from different group of mice ( n = 6/per group). Scale bar, 100 μm. Viteixn attenuated fibrosis in aged mice measured by Sirius red staining. Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (E and I) Cardiac, serum, colon MDA, SOD and GSH-px levels were quantified using commercial assay kits. ( n = 6/per group). Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (F) Representative western blot and quantification of Cx43, Nav1.5, Cav1.2, Serca-2A, Kv4.2, α-SMA, OLA1, Nrf2, GAPDH in ventricle and atria in the four groups ( n = 6/per group). GAPDH was used for internal normalization. Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (G) Experimental design for testing the anti-aging effect of Nrf2 activator and inhibitor on aged mice induced by 150 mg kg D-gal. Summary of inducibility of VPB, AF, and AVB in vitexin, DMF, ML385 treated aged mice. Numbers in parentheses indicate the number of mice that were induced into VPB, AF, AVB following ISO treated ( n = 6/per group). Data analyzed by Fischer’s exact test. (H) The examples of HE, Sirius red staining in the ventricle from different group of mice ( n = 6/per group). Scale bar, 100 μm. Viteixn and DMF attenuated fibrosis in aged mice measured by Sirius red staining. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. Serum levels were quantified using commercial assay kits. ( n = 6/per group). Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001. (J) Representative western blot and quantification of Cx43, Nav1.5, Cav1.2, Serca-2A, Kv4.2, α-SMA, OLA1, Nrf2, and GAPDH in ventricle in the four groups ( n = 6/per group). GAPDH was used for internal normalization. Data are presented as the mean ± SD. Data analyzed by one-way ANOVA with Tukey’s post-hoc test. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001.

    Article Snippet: Surface electrocardiogram (ECG) was monitored by P3 plus (Data Sciences International), 1.5% isoflurane-oxygen mixture was anesthetized, and subcutaneous platinum electrode was placed on lead II.

    Techniques: Blocking Assay, Staining, Western Blot

    Intracardiac programmed electrical stimuli results. (A) Representative burst pacing electrocardiogram wave. (B) AF incidence in the four groups. (C) AF duration in the four groups. n=20 for each group. Data are presented as mean ± SD. **P<0.01 vs. the control group; # P<0.05 vs. the DM group. DM, diabetes mellitus; AF, atrial fibrillation; H 2 S, hydrogen sulfide.

    Journal: Molecular Medicine Reports

    Article Title: Exogenous hydrogen sulfide reduces atrial remodeling and atrial fibrillation induced by diabetes mellitus via activation of the PI3K/Akt/eNOS pathway

    doi: 10.3892/mmr.2020.11291

    Figure Lengend Snippet: Intracardiac programmed electrical stimuli results. (A) Representative burst pacing electrocardiogram wave. (B) AF incidence in the four groups. (C) AF duration in the four groups. n=20 for each group. Data are presented as mean ± SD. **P<0.01 vs. the control group; # P<0.05 vs. the DM group. DM, diabetes mellitus; AF, atrial fibrillation; H 2 S, hydrogen sulfide.

    Article Snippet: Surface electrocardiogram (ECG; B&W TEKSystems, Inc.) and intracardiac electrograms were recorded simultaneously.

    Techniques: Control